<LOGO>
FM Transmitter Measurement Report
Created: 2025-04-24 18-11-23
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 53 dBuV VOLTAGE
Pilot RDS Phase Difference
6.4 kHz 3.8 kHz -9 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 71 kHz 10062 4,6313
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,2 dBr
MIN AVE MAX % above 10,2 dBr
6,7 dBr 7,62 dBr 8,3 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 0 (No PTY) 1 0 0 2 18:11, 24.04.2025
RT
"VOLTAGE - Addictive Radio "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 5/5 (53 dBuV) Max at: 71 kHz MIN: 12 kHz % above 76 kHz: 4,6313 Acquired: 2025/04/24 18:10:20 Total samples: 10062 Equivalent time: 0:08:23 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 8,3 dBr MIN: 6,7 dBr AVE: 7,62 dBr % above 10,2 dBr: 0,0 Last value: 7,0 dBr (2025/04/24 18:10:20) Station: 96.90 MHz, signal: 4/5 (52 dBuV) 18:03 18:04 18:05 18:06 18:07 18:08 18:09 18:10 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality